BACKGROUND. The circadian clock is a fundamental and pervasive biological program that coordinates 24-hour rhythms in physiology, metabolism, and behavior, and it is essential to health. Whereas therapy adapted to time of day is increasingly reported to be highly successful, it needs to be personalized, since internal circadian time is different for each individual. In addition, internal time is not a stable trait, but is influenced by many factors, including genetic predisposition, age, sex, environmental light levels, and season. An easy and convenient diagnostic tool is currently missing. METHODS. To establish a validated test, we followed a 3-stage biomarker development strategy: (a) using circadian transcriptomics of blood monocytes from 12 individuals in a constant routine protocol combined with machine learning approaches, we identified biomarkers for internal time; and these biomarkers (b) were migrated to a clinically relevant gene expression profiling platform (NanoString) and (c) were externally validated using an independent study with 28 early or late chronotypes. RESULTS. We developed a highly accurate and simple assay (BodyTime) to estimate the internal circadian time in humans from a single blood sample. Our assay needs only a small set of blood-based transcript biomarkers and is as accurate as the current gold standard method, dim-light melatonin onset, at smaller monetary, time, and sample-number cost. CONCLUSION. The BodyTime assay provides a new diagnostic tool for personalization of health care according to the patient’s circadian clock. FUNDING. This study was supported by the Bundesministerium für Bildung und Forschung, Germany (FKZ: 13N13160 and 13N13162) and Intellux GmbH, Germany.
Nicole Wittenbrink, Bharath Ananthasubramaniam, Mirjam Münch, Barbara Koller, Bert Maier, Charlotte Weschke, Frederik Bes, Jan de Zeeuw, Claudia Nowozin, Amely Wahnschaffe, Sophia Wisniewski, Mandy Zaleska, Osnat Bartok, Reut Ashwal-Fluss, Hedwig Lammert, Hanspeter Herzel, Michael Hummel, Sebastian Kadener, Dieter Kunz, Achim Kramer
Usage data is cumulative from March 2023 through March 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 2,277 | 622 |
700 | 133 | |
Figure | 335 | 14 |
Table | 120 | 0 |
Supplemental data | 362 | 63 |
Citation downloads | 100 | 0 |
Totals | 3,894 | 832 |
Total Views | 4,726 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.